TMS RamSan-400 °³¿ä
 

" The World's Fastest Storage "

3 Gigabytes per Second

400,000 IOPS

32 to 128 GB Storage

2-8 FC Links (4-Gb)

Hot-swap Modules

±¸ºÐ TMS RamSan-400
I/Os per second 400,000
Capacity 32-128 GB
Bandwidth 3 GB/sec
Fibre Channels : 4Gb 2Gb 2 to 8 Port
Latency  <14 micro sec
Disk Drives Redundant HOT-Swap
Power Supplies Redundant HOT-Swap
Batteries 3 Redundant
Size 5.25" (3U) x 25 "
Power Consumption (Peak) 350 Watts
Weight(maximum) 80 lbs
 
 
Solid State Disk Storage
  RamSan-400Àº ÃÊ°í¼Ó ÀúÀå ÀåÄ¡ÀÔ´Ï´Ù. ¸ðµç µ¥ÀÌÅÍÀÇ ÀúÀåÀº ±â°èÀû ȸÀü¹æ½ÄÀÎ Çϵåµð½ºÅ© ´ë½Å ºü¸¥ DDR RAMÀ» ÀúÀå¸Åü·Î ÇÕ´Ï´Ù. °í¼º´É ¼­¹ö¿Í ºñ½ÁÇÑ ¸Þ¸ð¸®¹ö½º ±¸Á¶·Î µÈ RamSan-400Àº ´ë·®ÀÇ I/O󸮿¡ ÃæºÐÇÑ ´ë¿ªÆø(3GB/s)À» °¡Áö°í ÀÖ½À´Ï´Ù. ªÀº Latency´Â ¼º´ÉÀúÇϾøÀÌ ¼ö½Ê´ëÀÇ ¼­¹ö¸¦ µ¿½Ã¿¡ Áö¿ø ÇÒ ¼ö ÀÖ½À´Ï´Ù. ªÀº Latency´Â µÎ °¡Áö ÀåÁ¡À» °¡Áö°í ÀÖ¾î »ç¿ëÀڵ鿡°Ô 100xºü¸¥ ÀÀ´ä½Ã°£À» Á¦°øÇÏ°í 100xÀÌ»óÀÇ ¸¹Àº »ç¿ëÀÚ°¡ °°Àº Volume¿¡ Access°¡´ÉÇÏ°Ô ÇÕ´Ï´Ù. RamSan-400Àº 2-8(4-Gb)°³ÀÇ Fibreä³Î Æ÷Æ®°¡ ÃÖ°í¼Óµµ·Î µ¿ÀÛÇÕ´Ï´Ù. RamSan-400Àº ÃÖ°íÀÇ ±â°èÀû µð½ºÅ©º¸´Ù ¹ÏÀ» ¼ö ¾øÀ»¸¸Å­ ¿ì¼öÇÑ ¼º´ÉÀ» Á¦°øÇÕ´Ï´Ù.
 
¼³Ä¡¿Í °ü¸®
 

RamSan-400Àº Çϵåµð½ºÅ© µå¶óÀ̺êó·³ ¼³Ä¡Çϱ⠽±½À´Ï´Ù. °£´ÜÇÑ ±¸¼º¿¡¼­´Â HBA¸¦ ÅëÇØ ÇÑ ¼­¹ö¿¡ Á÷Á¢ ¿¬°áÇÕ´Ï´Ù. È®ÀåµÈ ±¸¼º¿¡¼­´Â Fibreä³Î ½ºÀ§Ä¡¸¦ ÅëÇØ ¼ö¹é´ëÀÇ W/S¶Ç´Â ¼­¹ö¿¡ ¿¬°áÇÒ ¼ö ÀÖ½À´Ï´Ù. ±âº»Àû °ü¸®±â´É(¼öµ¿Á¤Áö, °æ°í¸Þ¼¼Áö È®Àεî)Àº Àü¸éÀÇ LCDÆÇ³Ú ½ºÅ©¸°À» ÅëÇØ ÀÌ¿ë °¡´ÉÇÕ´Ï´Ù. ¿Ïº®ÇÑ ¸ð´ÏÅ͸µ°ú ȯ°æ¼³Á¤Àº Protected JAVA AppletÀ» ÀÌ¿ëÇÑ ºê¶ó¿ìÀú·Îµµ °¡´ÉÇÕ´Ï´Ù. RamSan-400´Â SNMP¿Í ¿Ïº®È÷ ȣȯµË´Ï´Ù.

 
°í ¾ÈÁ¤¼º ÀúÀåÀåÄ¡
 

¾î¶² ÀúÀå ÀåÄ¡¿¡¼­µµ ¾ÈÁ¤¼ºÀº ±âº»Àû °ü½É ´ë»óÀÔ´Ï´Ù. RamSan-400Àº ´Ù¸¥ SSD³ª RAID ÀåÄ¡º¸´Ù ¿ì¼öÇÑ ¾ÈÁ¤¼ºÀ» Á¦°øÇÏ°Ô ¼³°èµÇ¾î ÀÖ½À´Ï´Ù. ±âº» ±â´ÉÀ¸·Î Chipkill-protected RAM, Hot-Swap Àü¿øÀåÄ¡, Fibre ä³Î Æ÷Æ®ÀÇ Failover±â´É, SNMP ȣȯ¼º, 3°³ÀÇ Àå¾Öº¸¿Ï±¸Á¶ÀÇ ³»ºÎ ¹èÅ͸®, Hot-SwapÀÌ °¡´ÉÇÑ 4°³ÀÇ ¹é¾÷ Çϵåµð½ºÅ©¸¦ Æ÷ÇÔÇÕ´Ï´Ù.

 
ÀüÇüÀûÀÎ ÀúÀå °èÃþ±¸Á¶
 

ÄÄÇ»ÅÍÀÇ ¼º´ÉÀº ȸÀü±¸Á¶ÀÇ Çϵåµð½ºÅ© ¼º´Éº¸´Ù ÈξÀ »¡¸® ¹ßÀüÇÔÀ¸·Î½á ÀüÅëÀûÀÎ 2-´Ü°è ÀúÀå °èÃþ±¸Á¶´Â »õ·Î¿î Performance LevelÀ» ÇÊ¿ä·Î ÇÏ°Ô µÇ¾ú½À´Ï´Ù. High PerformanceÀÇ RamSan-400Àº ÀÌ ¿ä±¸¸¦ ÃæÁ·ÇϹǷΠ»ç¿ëÀÚ°¡ 3´Ü°è ÀúÀ屸Á¶¸¦ ±¸¼º ÇÒ ¼ö ÀÖµµ·Ï ÇÕ´Ï´Ù. °úºÎÇÏ »óÅ¿¡¼­µµ RamSan-400ÀÇ I/OÆÄ¿ö¿Í ´ë¿ªÆøÀº ÄÄÇ»ÅÍ°¡ Áï°¢ÀûÀ¸·Î, ¶ÇÇÑ µ¿½Ã¿¡ Highly Active Data FilesµéÀ» Access °¡´ÉÇÏ°Ô ÇÕ´Ï´Ù.

 
ºñÈֹ߼º ¹é¾÷ ¹æ½Ä
 

RamSan-400¿¡ RAMÀ» »ç¿ëÇϹǷνá ÃÖ°í ¼º´ÉÀ» ¹ßÈÖÇϵµ·Ï ÇÏ¿´½À´Ï´Ù. ÀϹÝÀûÀ¸·Î RAMÀåÄ¡´Â Á¤Àü½Ã µ¥ÀÌÅ͸¦ ÀÒ°Ô µÇÁö¸¸, ºñÈֹ߼ºÀ» À§ÇØ È®½ÇÇÑ Àå¾Öº¸¿Ï±¸Á¶ÀÇ ¹èÅ͸®¿Í 2°¡ÁöÀÇ ¹é¾÷¹æ¹ýÀ¸·Î Àå¾Öº¸¿Ï±¸Á¶ÀÇ ³»ºÎ RAID µð½ºÅ©, LUN ´ÜÀ§ÀÇ ±¸¼º ¹æ¹ýÀÌ ÀÖ¾î, »ç¿ëÀÚ¿¡°Ô ¾ÆÁÖ ´Ù¾çÇÏ°í È®½ÇÇÑ ½Å·Ú¸¦ Á¦°øÇÕ´Ï´Ù.

 
Fibre ä³Î ¿¬°á
 
4Gb Fibre ä³Î (2Gbµµ °¡´É)
2°³ÀÇ Æ÷Æ® ±âº» : 8Æ÷Æ®±îÁö È®Àå°¡´É
Point to Point, Arbitrated Loop, Switched Fabric Topology
Fibre Channel Host Adapter, ½ºÀ§Ä¡, OS Á¾·ùµî¿¡ ±¸¾Ö¾øÀÌ ±¸¼º°¡´É
°ü¸®
 
ºê¶ó¿ìÀú¿¡¼­ ½Ã½ºÅÛ ¸ð´ÏÅ͸µ, °ü¸®, Configuration
SNMP Á¦°ø
TelnetÀ¸·Î Á¢¼Ó/°ü¸® °¡´É
ÇÁ·ÐÆ® ÆгÎÀº ½Ã½ºÅÛ»óŸ¦ Ç¥½ÃÇÏ°í ±âº»ÀûÀÎ Á¶ÀÛ±â´ÉÀ» Á¦°ø
LUN Á¦°ø
 
1∼64 LUNs±¸¼ºÀÌ °¡´ÉÇϸç, ´Ù¾çÇÑ ¿ë·®À¸·Î LUN±¸¼º°¡´É
Portµé°ú LUNµé°£¿¡ FlexibleÇÑ Assignment
Çϵå¿þ¾î LUN Masking
µ¥ÀÌÅÍ º¸È£¼º
 
ºñÈֹ߼º ¸Þ¸ð¸® ÀúÀåÀåÄ¡
Àü¿øÀå¾Ö½Ã Àå¾Öº¸¿Ï ±¸Á¶ÀÇ ³»ºÎ ¹èÅ͸® Àü¿ø°ø±Þ
Àü¿øÀå¾Ö³ª Manual shutdown½Ã, ÀÚµ¿ÀûÀ¸·Î ³»ºÎ µð½ºÅ©¿¡ µ¥ÀÌÅÍ ¹é¾÷
½Å·Ú¼º°ú °¡¿ë¼º
 
°í °¡¿ë¼º ±¸Á¶
Chipkill™±â¼úÀº Memory errors¹ß»ý½Ã Memory Chip Àå¾Ö·ÎºÎÅÍÀÇ Data¸¦ º¸È£
³»ºÎ Àå¾Öº¸¿Ï ÀåÄ¡
- Àü¿ø °ø±ÞÀåÄ¡¿Í ³Ã°¢ÆÒ
- ¹é¾÷ ¹èÅ͸® Àü¿ø(n+1)
- ¹é¾÷ Çϵåµð½ºÅ© µå¶óÀ̺ê (RAID3)
Hot Swap °¡´É ±¸¼ºÇ°
- ¹é¾÷ Çϵåµð½ºÅ© µå¶óÀ̺ê(Àü¸é¿¡¼­ ±³È¯°¡´É)
- Àü¿ø °ø±ÞÀåÄ¡
Active : Passive±¸¼ºÀÇ Fibre Channel Àå¾ÖÀüȯ(¿É¼Ç)
¹é¾÷ ÀýÂ÷
  ½Ã½ºÅÛ´ç ¶Ç´Â LUN´ç ±¸¼ºÇÒ ¼ö ÀÖ´Â µÎ°¡Áö ¹é¾÷¹æ¹ýÀ» Á¦°øÇÕ´Ï´Ù.
Data Sync Mode
- Shutdown ¶Ç´Â Àü¿ø°ø±ÞÀÌ ²÷±æ ¶§ ³»ºÎµð½ºÅ© µå¶óÀÌºê µ¥ÀÌÅ͸¦ Synchronize
Active Backup™ Mode(¿É¼Ç)
- ½Ã½ºÅÛ ¼º´É¿¡ ¿µÇâ¾øÀÌ Àå¾Öº¸¿Ï ±¸Á¶ÀÇ ³»ºÎµð½ºÅ©·Î »ó½Ã µ¥ÀÌÅ͸¦ ¹é¾÷ÇÕ´Ï´Ù.
 
 
 